Parameter | Through-Beam Type | Mirror Reflection Type | Diffuse Reflection Type |
Model (NPN) | - | KN-LT61 | KN-LR61 |
Detection Object | 10x10mm white drawing paper | 10x10mm white drawing paper | Opaque objects with diameter >2mm |
Light Source (Wavelength) | 660nm red laser (for all types) | ||
Power Supply Voltage | DC12-24V (ripple (p-p) ≤10%); DC10-30V (wide voltage range) (for all types) | ||
Control Output | Load current ≤150mA (residual voltage ≤1V) (for all types) | ||
Circuit Protection | Surge protection, short-circuit protection, reverse polarity protection (for all types) | ||
Response Time | On/Off response: ≤1.0ms each (for all types) | ||
Indicator Light | Operation indicator (red) (for all types) | ||
Ambient Light Influence | Incandescent light: ≤3000lx (for all types) | ||
Ambient Humidity | Operating: 45%-85%RH (no freezing); Storage: 35%-85%RH (no freezing) (for all types) | ||
Voltage Influence | When the power supply fluctuates within ±15% of the rated voltage, the detection distance changes within ±1% (for all types) | ||
Insulation Resistance | ≥20MΩ (between live parts and housing, measured with DC500V megohmmeter) (for all types) | ||
Dielectric Strength | ≥AC1000V, 50/60Hz for 1 minute (between live parts and housing) (for all types) | ||
Vibration Resistance (Durability) | 10~50Hz, 1.5mm double amplitude, 1 hour each in X, Y, Z directions (for all types) | ||
Shock Resistance (Durability) | 500m/s², 3 times each in X, Y, Z directions (for all types) | ||
Protection Class | IP65 (for all types) | ||
Connection Method | Lead wire type (standard length: 2m) (for all types) | ||
Housing Material | ABS (for all types) |